RKI M2 Series Fixed Gas Sensor Transmitter

Available - Usually ships in 1 - 2 days
SKU
RKI01-65-2640RK
$925.00
The M2 sensor/transmitters from RKI Instruments are fixed system, stand-alone, explosion-proof gas monitors that provide direct read-out, and can function alone, or as a part of an integrated system with a controller.

M2 sensor/transmitters are able to connect to virtually any controller, PLC, or DCS, but are designed to work with the Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers from RKI.

Installation and maintenance of the M2 series monitors is simple. Calibrations utilizes a magnetic wand technique for performing that doesn't require opening up the sealed housing. Because the unit does not need to be opened for zeroing or calibration, it is not necessary to declassify the surrounding area to perform routine maintenance.

Key Features:
  • Independent, stand-alone fixed gas monitor system
  • Toxic gases include Cl2, NH3, SO2, HCN, and more
  • Infrared sensor for combustibles and CO2
  • Connects to virtually any controller, PLC, or DCS
  • Non-intrusive magnetic calibration
  • 4-20 mA and Modbus digital outputs
  • High specificity
  • Long life sensors
  • Fast response
  • Direct readout on backlit LED screen and can be transmit to controller
  • Available gases include % LEL, H2S, CO, PPM HC, & CO2
Description: LEL General Purpose
Measuring Range: 0-100% LEL
Accuracy: +/-5% of reading or 2% LEL
Lower Detectable Limit (LDL): 2% of full scale
Response Time: 35 seconds or less
Life Expectancy: 2-3 years with normal exposure to natural gas
Part Numbers:
65-2640RK

Description: LEL, H2 Specific
Measuring Range: 0-100% LEL (H2 Specific)
Accuracy: +/-5% of reading or 2% LEL
Lower Detectable Limit (LDL): 2% of full scale
Response Time: 35 seconds or less
Life Expectancy: 3-5 years with normal service
Part Numbers:
65-2641RK

Description: Oxygen (O2)
Measuring Range: 0-25% volume
Accuracy: +/-0.5% O2
Lower Detectable Limit (LDL): 0.1% volume
Response Time: 35 seconds or less
Life Expectancy: 2-3 years with normal service
Part Numbers:
65-2643RK-05

Description: Hydrogen Sulfide (H2S)
Measuring Range: 0-100 ppm
Resolution: 1 ppm
Lower Detectable Limit (LDL): 2% of full scale
Response Time: 35 seconds or less
Life Expectancy: 2-3 years with normal service
Part Numbers:
65-2645RK-05

Description: Carbon Monoxide (CO)
Measuring Range: 0-300 ppm
Lower Detectable Limit (LDL): 2% of full scale
Response Time: 35 seconds or less
Life Expectancy: 2-3 years with normal service
Part Numbers:
65-2646RK-05

Description: Methane (CH4)
Measuring Range: 0-100% LEL / 0-100% volume
Accuracy: +/- 5% of reading or +/- 2% of full scale
Lower Detectable Limit (LDL): 2% of full scale
Response Time: 30 seconds
Life Expectancy: 5+ years with normal service
Part Numbers:
65-2649RK-CH4
65-2658RK-CH4

Description: Hydrocarbons (HC)
Measuring Range: 0-100% LEL / 0-100% volume
Accuracy: +/- 5% of reading or +/- 2% of full scale
Lower Detectable Limit (LDL): 2% of full scale
Response Time: 30 seconds or less
Life Expectancy: 5+ years with normal service
Part Numbers:
65-2649RK-HC

Description: Carbon Dioxide (CO)
Measuring Range: 0-5000 ppm, 0-5.0% Vol., 0-50% Vol., 0-100% Vol.
Resolution: 20 ppm / 0.1% volume
Lower Detectable Limit (LDL): 2% of full scale
Response Time: 30 seconds
Life Expectancy: 5+ years with normal service
Part Numbers:
65-2660RK-02 - 0-5000 ppm
65-2660RK-03 - 0-5.0% Vol.
65-2660RK-05 - 0-50% Vol.
65-2660RK-10 - 0-100% Vol.
More Information
Price $925.00
SKU RKI01-65-2640RK
Product Weight (lbs.) 6.0
Weight 10.0000
Brand RKI Instruments
MPN 65-2640RK
Type Single-Gas
Gas Type No
5th Sensor No
Color No
Write Your Own Review
You're reviewing:RKI M2 Series Fixed Gas Sensor Transmitter
Your Rating
Questions

1 Item

Show per page
  1. Tracey Lemmon

    2014-06-19 15:21:13

    Can I get cut sheets on RKI M2 gas sensor.
    Does it need to be field calibrated?

    1 answer
    1. Justin

      2014-06-19 15:21:13

      Here’s a link to the data sheet: http://www.rkiinstruments.com/pdf/M2.pdf<br>
      <br>
      Like all gas monitors, the M2 does need to be calibrated. It can be calibrated in the field, and because it doesn’t have to be opened for zeroing or adjustment, it’s not necessary to shut down and declassify the area for maintenance.